Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.
Scientific Reports volume 14, Article number: 11442 (2024 ) Cite this article coating chamber
The global supply of fluoropolymers and fluorinated solvents is decreasing due to environmental concerns regarding polyfluoroalkyl substances. CYTOP has been used for decades primarily as a component of a femtoliter chamber array for digital bioanalysis; however, its supply has recently become scarce, increasing the urgency of fabricating a femtoliter chamber array using alternative materials. In this study, we investigated the feasibility of fabricating a femtoliter chamber array using four types of fluoropolymers in stable supply as candidate substitutes and verified their applicability for digital bioanalysis. Among these candidates, Fluorine Sealant emerged as a viable option for fabricating femtoliter chamber arrays using a conventional photolithography process. To validate its efficacy, we performed various digital bioanalysis using FP-A-based chamber arrays with model enzymes such as CRISPR–Cas, horseradish peroxidase, and β-galactosidase. The results demonstrated the similar performance to that of CYTOP, highlighting the broader utility of FP-A in digital bioanalysis. Our findings underscore the potential of FP-A to enhance the versatility of digital bioanalysis and foster the ongoing advancement of innovative diagnostic technologies.
Digital bioanalysis using femtoliter chamber arrays has emerged as a transformative tool that plays a pivotal role in advancing several areas of life sciences1,2. This innovative approach has demonstrated a significant impact on single molecule biophysics, providing insights into biomolecules with unprecedented sensitivity and precision3,4,5,6,7,8. Additionally, the impact of digital bioanalysis is reverberating in the field of disease diagnostics, and the technique has emerged as an invaluable testing platform for infectious diseases and latent disorders5,6. Its innate capacity for high sensitivity and precision enables the detection of even the rarest biomarkers or pathogens, thereby facilitating early disease diagnosis and continuous disease monitoring. The versatility of digital bioanalysis underscores its importance in advancing both basic research and medical applications.
Femtoliter chamber arrays for digital bioanalysis can be classified into two main types: (i) those fabricated by photolithography of fluoropolymers9 and (ii) those fabricated by injection molding of plastics such as cyclo-olefin polymer (COP)10 and polycarbonate (PC)11,12. In terms of the cost of manufacturing equipment and well-established manufacturing processes, femtoliter chamber arrays made of fluoropolymers have been widely used in basic research for decades2,13. Recently, the global supply of fluoropolymers and fluorinated solvents has decreased because of environmental concerns regarding polyfluoroalkyl substances (PFAS)14. CYTOP has historically played a central role as a component of femtoliter chamber arrays2,13; however, recent scarcity in the supply chain has heightened the necessity of exploring alternative materials for fabricating femtoliter chamber arrays. This exploration could contribute significantly to the sustainability of research and development in digital bioanalysis.
In this study, we investigated the feasibility of fabricating a femtoliter chamber array using four types of fluoropolymers with a stable supply. Successfully fabricated femtoliter chamber arrays were used to verify the feasibility of digital bioanalysis, demonstrating a performance similar to that of conventional CYTOP. Thus, it is applicable as an alternative to digital bioanalysis.
Various methods are used for the formation of thin polymer films, including spin-coating, dip-coating, spray-coating, and bar-coating. In this study, thin films were formed on glass substrates using four types of fluoropolymers as alternatives to CYTOP by spin coating, which is a widely utilized technique for fabricating femtoliter chamber arrays (Fig. 1). Four types of fluoropolymers, FP-A (Fluorine Sealant DKA-001, DAIKIN INDUSTRIES), FP-B (SFCOAT SFE-GP03JL, AGC seimi chemical), FP-C (SURECO 2101S, AGC), and FP-D (SURECO 2120X, AGC), are commercially available that are mainly used for moisture-proof coatings of electronic substrates. Because a high water-contact-angle is preferred as a component of a femtoliter chamber array, we selected the fluoropolymers with contact angles above 110° (FP-A: 115°, FP-B: 117°, FP-C and D: 113°), which is equivalent to that of conventional CYTOP (112°).
Spin-coating of fluoropolymer on glass substrate. (A) Photographs of spin-coated glass substrate. Scale bar represent 10 mm. (B) Thickness of fluoropolymer film plotted against spin speed. Green, red, and black represent CYTOP, FP-A, and FP-B, respectively (n = 3 replicates).
FP-A and FP-B were able to form thin films with a uniform thickness between 0.4 and 1.1 µm on glass substrates by spin coating (Fig. 1), whereas FP-C and FP-D failed owing to a low concentration of fluoropolymer or low substrate affinity. The film thicknesses of FP-A and FP-B decreased with increasing spin speed, indicating that the film thickness was controlled by the spin-speed. At a low spin speed of 1000 rpm, the film thickness of CYTOP was twice those of FP-A and FP-B. A possible reason for this discrepancy could be the high boiling point of the solvent of CYTOP (Ct-Solv180, 174 °C) compared to that of FP-A (Novec 7200, 76 °C) and FP-B (mixture, 127 °C), which could affect the viscosity during spin-coating.
Using conventional photolithography, we fabricated femtoliter-volume chamber arrays made of fluoropolymers (FP-A and FP-B) that can be used to form uniform thin films as described above (Figs. 2A, S1, and S2). Femtoliter chamber arrays can be fabricated with the fluoropolymers via a photolithographic process similar to that previously reported for CYTOP with chamber volumes of 2.8–6.7 fL (Fig. S3); however, some problems were encountered with each fluoropolymer. For FP-A, if the solvent was not sufficiently removed after spin-coating, the film shrank when exposed to vacuum conditions in the RIE machine, resulting in cracks in the deposited photoresist film on top of the FP-A (Fig. S4). Therefore, it was necessary to sufficiently remove the solvent by heating the substrate at 70 °C for more than 12 h. Film formation of the photoresist was another challenge owing to the poor adhesion to FP-A after prolonged baking. To improve adhesion to FP-A, a fluorinated surfactant (Surflon S386) was added to the photoresist to form a thin film. In addition, during dry-etching, the mesh structure remained on the bottom surface of the glass regardless of the processing time (Fig. S5). Therefore, ultrasonic treatment with a strongly alkaline solution after dry-etching was necessary to remove the mesh structure and form the uniform through-hole structures. In contrast, for FP-B, numerous small protrusions occurred on the surface of the membrane, producing approximately 0.3% defects (Fig. S6).
Femtoliter chamber arrays. (A) SEM images of femtoliter chambers fabricated with CYTOP, FP-A and FP-B films, respectively. Scale bars represent 1 μm. (B) Fluorescence images of FP-A chambers filled with 10 µM Alexa 488 during the FRAP assay. Scale bars represent 10 µm. (C) Time course of fluorescence intensity of Alexa 488 with (light grey and grey represent 35 chambers and their average, respectively) or without photobleaching (light green and green represent 35 chambers and their average, respectively). Black allows indicate the timing of photobleaching.
For digital bioanalysis, the reaction solution was dropped into an array of chambers and then replaced with oil to fractionate and retain the solution in each chamber. Because the stable retention of the reaction solution depends on the composition of the chamber and the type of oil, femtoliter chamber arrays with similar volumes (V: 4–5 fL) were fabricated using CYTOP, FP-A, and FP-B, to investigate the retention times of the reaction solutions in each chamber (Fig. 2B,C). When an aqueous solution containing a green fluorescent dye (Alexa 488), was used as an indicator and fractionated into chambers using Fomblin oil, which is commonly used in digital bioanalysis, the fluorescence intensity of the chambers remained stable for longer than 30 min regardless of the type of fluoropolymer (Fig. 2B,C), indicating the stable retention of solutes in the chambers. In addition, a fluorescence recovery after photobleaching (FRAP) assay was performed to ensure that the chambers were hermetically sealed and not conducting. The femtoliter chambers were filled with a solution containing 10 µM Alexa 488, and some of them were selectively photobleached using the laser scanning system of a confocal microscope (Fig. 2B,C). Subsequent analysis of fluorescence intensity showed that the bleached chamber did not recover its fluorescence in ~ 30 min, confirming that the chamber was hermetically sealed with Fomblin oil.
The efficiency of encapsulation of the fluorescent dye solution in the chambers can affect the reproducibility and quantitation of digital bioanalysis. To investigate the efficiency, the fluorescence intensity was measured using 4–5 fL chamber arrays, encapsulated with a solution containing the indicated concentration of Alexa 488 (Fig. 3A). The fluorescence intensity increased proportionally with the concentration of Alexa 488, regardless of the type of fluoropolymer. However, the fluorescence intensity of FP-A was comparable to that of CYTOP, whereas that of FP-B was approximately one tenth (Fig. 3B). The lower fluorescence intensity in FP-B may be attributed to the open-front structure of the chamber (Fig. 2A), which may allow oil to enter the chamber through the opening, resulting in a low actual volume of the dye solution in the chamber.
Fluorescence imaging. (A) Representative fluorescence images and (B) fluorescence intensities of femtoliter chamber arrays prepared using CYTOP, FP-A or FP-B with an indicated concentration of Alexa 488. Solid lines show linear regressions. Scale bars represent 100 µm. (C) Ratio of autofluorescence intensity to CYTOP (n = 3 technical replicates).
The autofluorescence of fluoropolymers can also affect fluorescence imaging, resulting in lower sensitivity of digital bioanalysis. Autofluorescence was measured using four laser light sources widely used in digital bioanalysis: 405, 488, 561, and 640 nm (Fig. 3C). FP-B showed a similar or lower autofluorescence intensity than CYTOP at all wavelengths, whereas FP-A showed a higher, especially at shorter wavelengths. However, the autofluorescence for all fluoropolymers, even for FP-A, was almost negligible compared to the signal from the fluorescent dyes (Fig. 3A,B), demonstrating the feasibility of digital bioanalysis with new fluoropolymers. Collectively, FP-A has the potential to be used as an alternative to CYTOP for digital bioanalysis owing to its fluorescence properties.
Digital bioanalysis is an exceptionally sensitive approach that can fractionate target biomolecules of interest at the single-molecule level for subsequent detection by coupling to the fluorogenic reaction of enzymes1,2. The detection modalities of digital bioanalysis can be broadly classified as (i) direct detection of target enzymes and (ii) indirect detection of target molecules by fluorogenic enzymes15.
Direct detection of target enzymes is based on a fluorogenic reaction within femtoliter chamber arrays. In this modality, the solution containing target enzyme and fluorogenic substrate was dropped onto the arrays and confined to the chambers by dropping an oil. The concentration of the target enzyme in the sample can be accurately quantified with high sensitivity by counting the number of positive chambers that exhibit a fluorescent signal resulting from the enzymatic reaction. This method has recently been applied to the highly sensitive detection of disease-related enzymes in blood5,16,17, opening up possibilities for early disease diagnosis. As a proof of concept of the first modality, the femtoliter chamber arrays prepared using FP-A and CYTOP were used for the direct detection of model enzymes commonly used in digital bioanalysis, i.e. horseradish peroxidase (HRP) and β-galactosidase (β-Gal)2 (Fig. 4A). The number of positive chambers increased linearly over a wide range of concentration of target enzymes, regardless of the fluoropolymer type (Fig. 4B,C). The number of positive chambers for β-Gal exceeded the theoretical values based on the Poisson distribution by more than 10 times, whereas HRP showed almost identical results. A possible reason for this discrepancy is that the non-specific binding of β-Gal to fluoropolymers is more likely than that of HRP, resulting in a higher number of positive chambers. The limit of detection (LoD) was nearly identical for HRP (~ 9.5 fM) and β-Gal (~ 0.3 fM) regardless of fluoropolymer type (Fig. 4C), suggesting that FP-A could be used as an alternative to CYTOP for femtoliter chamber arrays in digital bioanalysis.
Digital enzyme detection of HPR and β-Gal. (A) Schematics of digital enzyme detection assay. (B) Representative fluorescence images at each concentration of enzyme using FP-A. Scale bars represent 100 µm. (C) Number of positive chambers obtained using β-Gal_CYTOP (green), β-Gal_FP-A (red), HRP_CYTOP (yellow), or HRP_FP-A (blue). The solid lines show the linear regressions in red, green, yellow, and red and the theoretical value in grey. The dotted lines show the values of the blank mean + 3 SD (n = 3 technical replicates).
Amplification-free digital viral RNA detection (SATORI). (A) Schematics of SATORI assay. (B) Representative fluorescence images at each concentration of viral RNA using CYTOP and FP-A. Scale bars represent 100 µm. (C) Number of positive chambers obtained using CYTOP (green) or FP-A (red). The solid lines show the linear regressions in green and red and the theoretical value in grey. The dotted lines show the values of the blank mean + 3 SD (n = 3 technical replicates).
We developed highly integrated femtoliter chamber arrays using various fluoropolymers commercially available. Among fluoropolymers tested, we found that FP-A is suitable for forming femtoliter chamber arrays. As a proof-of-concept, various digital bioanalyses were performed using the FP-A-based chamber array with model fluorogenic enzymes, including HRP, β-Gal, and Cas13a. The results demonstrated the similar performance to that of CYTOP with a LoD ranging from sub-fM to 10-fM, highlighting the broader utility of FP-A as an alternative to CYTOP in highly sensitive digital bioanalysis.
Femtoliter chamber arrays using PF-A have lower material costs than the conventional CYTOP; however, formation of thin films and the smooth performance of the photolithographic process remain a challenge. Therefore, it is necessary to develop low-cost and high-quality femtoliter chamber arrays by further optimizing the photolithographic conditions, as well as developing and exploring new materials with higher functionality. Collectively, these continuous efforts to improve femtoliter chamber arrays will pave the way for low-cost and robust digital bioanalysis, thereby contributing to the realization of more versatile diagnostics.
While environmental concerns are paramount, it's important to recognize supply chain challenges, including the availability of materials and reagent due to globalization. Delays in the supply of fluoropolymers and solvents from specific manufacturers, triggered by PFAS regulations14 primarily in Europe, highlight the critical need to establish a system capable of utilizing multiple materials from various manufacturers. This approach is essential to ensure the sustainability of various research and development efforts that will expand the versatility of digital bioanalysis and further provide fundamental knowledge for biomedical applications.
The through-hole structures of the fluoropolymers, used as a femtoliter chamber, were fabricated on a thin glass substrate using conventional photolithography20. The fabrication process comprised four steps: (i) spin coating of the fluoropolymer, (ii) spin coating of the photoresist, (iii) UV exposure and development, and (iv) dry etching.
A 32 mm × 24 mm cover glass (No. 1, Matsunami) was incubated overnight, sonicated for 1 h in 8 M KOH solution, rinsed with pure water, and dried using an air blow gun. For CYTOP (9% CYTOP, AGC), it was spin-coated on the glass at 1000 rpm, 4000 rpm, or 7000 rpm for 30 s, and then baked at 80 °C for 10 min and 180 °C for 1 h. Positive photoresist (AZ P4620, AZ Electronic Materials) was spin-coated on the CYTOP layer at 7500 rpm for 30 s, and then cured at 100 °C for 5 min. After rehydration of the photoresist at 25 °C for more than 5 min under 60% humidity, the glass was exposed to UV light, using a mask aligner (LA610dt, Nanometric Technology) and a chrome photomask with 1.5 μm holes, followed by incubation for 1.5 min in a developer (AZ300 MIF, AZ Electronic Materials). The area not covered by the photoresist was removed via dry etching with O2 plasma (RIE-10NR, Samco). Dry etching was performed at an O2 flow rate of 50 sccm, gas pressure of 10 Pa, RF power of 50 W, and etching time of 16 min. The fabrication of the femtoliter chamber array was completed by removing the remaining photoresist via sequential rinsing with acetone, 2-propanol, and pure water. The chamber volumes (8.8 fL, 4.2 fL, or 2.4 fL for 1000 rpm, 4000 rpm, or 7000 rpm, respectively) were determined using a laser microscope (VK-X1100, Keyence).
For FP-A (95% Fluorine Sealant DKA-001, DAIKIN INDUSTRIES), it was diluted 20 times with a fluorinated solvent (Novec 7200, 3 M), spin-coated on the glass at 1000 rpm, 4000 rpm, or 7000 rpm for 30 s, and then baked at 30 °C for 60 min and 70 °C for more than 12 h. Positive photoresist (AZ P4620, AZ Electronic Materials) mixed with 0.1% fluorosurfactant (Surflon S386, AGC seimi chemical) was spin-coated on the FP-A layer at 7500 rpm for 30 s. The temperature of the photoresist-coated glass was raised continuously from 40 to 100 °C using a hotplate, followed by curing for more than 5 min. After rehydration of the photoresist at 25 °C for 5 min under 60% humidity, the glass was exposed to UV light, using a mask aligner (LA610dt, Nanometric Technology) and a chrome photomask with 1.5 μm holes, and then incubated for 0.75 min in a developer (AZ300 MIF, AZ Electronic Materials). The area not covered by the photoresist was removed via dry etching with O2 plasma (RIE-10NR, Samco). Dry etching was performed at an O2 flow rate of 150 sccm, gas pressure of 10 Pa, RF power of 80 W, and etching time of 15 min. The remaining photoresist was removed via sequential rinsing with acetone, 2-propanol, and pure water. The fabrication of the femtoliter chamber array was completed by sonication with pure water for 5 min and with 4 M KOH solution for 10 min, followed by rinsing with pure water, and drying using an air blow gun. The chamber volumes were 5.1, 2.8, or 3.8 fL for 1000, 4000, or 7000 rpm, respectively.
For FP-B (13% SFCOAT SFE-GP03JL AGC seimi chemical), it was diluted 1.5 times with a fluorinated solvent (Ct-Solv180, AGC), spin-coated on the glass at 1000 rpm, 4000 rpm, or 7000 rpm for 30 s, and then baked at 80 °C for 10 min and 180 °C for 1 h. Positive photoresist (AZ P4620, AZ Electronic Materials) was spin-coated on the FP-B layer at 7500 rpm for 30 s, and then cured at 100 °C for 5 min. After rehydration of the photoresist at 25 °C for 5 min under 60% humidity, the glass was exposed to UV light, using a mask aligner (LA610dt, Nanometric Technology) and a chrome photomask with 1.5 μm holes, and then incubated for 1.5 min in a developer (AZ300 MIF, AZ Electronic Materials). The area not covered by the photoresist was removed via dry etching with O2 plasma (RIE-10NR, Samco). Dry etching was performed with an O2 flow rate of 50 sccm, gas pressure of 10 Pa, RF power of 50 W, and etching time of 3 min at a spin speed of 1000 rpm, and 5 min at a spin speed of 4000 rpm and 7000 rpm. The fabrication of the femtoliter chamber array was completed by removing the remaining photoresist via sequential rinsing with acetone, 2-propanol, and pure water. The chamber volumes were 6.7 fL or 5.4 fL at 4000 rpm, or 7000 rpm, respectively.
For FP-C (0.1% SURECO 2101S, AGC), the film thickness was not enough to be analyzed with the laser microscope, regardless of the spin speed. For FP-D (20% SURECO 2120X, AGC), the thin film collapsed and droplets formed when it was baked on a hotplate.
After the photolithography process, 7-mm ring-shaped enclosures were fabricated as a reaction well on the substrate using a UV-curable acrylic resin (5X649H, CHEMITECH) and a dispensing robot (SHOTmini 200SX SM200S, Musashi Engineering).
A thin platinum layer was formed on the surface of the femtoliter chamber array via sputtering (JEC-3000FC, JEOL). High magnification and resolution images of the femtoliter chamber array were captured using a scanning electron microscope (JSM-IT210, JEOL) with 20 kV acceleration in a high vacuum environment.
The fluorescent dye solutions were prepared by dissolving indicated amount of Alexa Fluor™ 488 C 5 Maleimide (Alexa 488) and Alexa Fluor™ 568 C 5 Maleimide (Alexa 568) in buffer A (20 mM HEPES–KOH [pH 6.8], 100 mM KCl, 10 mM MgCl2, and 50 µM Triton X-100). The 105 μL of the fluorescent dye solution was dropped onto a femtoliter chamber array. Then, 95 μL was removed, and 50 μL of Fomblin oil (Y LVAC 25/6, Solvay) was added to seal the chamber. The excess solution and Fomblin oil left on the array were removed. After 1 min of incubation, fluorescence images (10-bit TIFF) were acquired with 488 nm (green) and 561 nm lasers (orange) using confocal microscope (A1HD25, Nikon) with a 20 × objective lens (NA = 0.75). There were more than 12,000 femtoliter chambers in one field of view.
The fluorescence images were analyzed using the ImageJ software (National Institute of Health), as follows: The orange images were processed using the ImageJ setThreshold command (parameters: 400–65,535 for CYTOP, 1200–65,535 for FP-A, and 200–65,535 for FP-B), and Analyze Particles command (parameters: size = 10–200, circularity = 0.30–1.00) to determine the location of femtoliter chambers. The ROI of the orange images were used for the green images in the same field of view, which were then processed using the roiManager command (parameter: Measure) to measure the fluorescence intensity of Alexa 488 in the chambers.
The femtoliter chambers were filled with buffer A containing 10 µM Alexa 488 and 2 µM Alexa 568 and then sealed with Fomblin oil. After 3 min of fluorescence imaging, the central rectangular area was selectively photobleached for approximately 50 s using the laser scanning system of the confocal microscope. Fluorescence images were acquired at intervals of 60 s over 20 min.
Autofluorescence images of femtoliter chamber arrays were acquired using a confocal microscope at four excitation wavelengths (405, 488, 561, and 640 nm). The ratios of the autofluorescence intensities of FP-A and FP-B to that of CYTOP were then calculated.
For the expression of LtrCas13a, Escherichia coli Rosetta 2 (DE3) was transformed with the pET-LtrCas13a plasmid, and the cells were cultured in a 2.5 L of LB medium containing kanamycin. When the OD600 values reached 0.6–1.0, the cells were cooled on ice for 10 min and further cultured at 20 °C for 20 h with 0.1 mM IPTG. Bacterial cells were collected by centrifugation, suspended in 40 mL of buffer B (20 mM Tris–HCl [pH 8.0], 1 M NaCl, 20 mM imidazole, 3 mM β-mercaptoethanol, and 1 mM phenylmethylsulfonyl fluoride), and lysed via sonication (Q500, QSONICA). After centrifugation at 15,000 rpm for 20 min, the supernatant was incubated with Ni–NTA agarose (Qiagen) at 4 °C for 1 h. The mixture was then transferred to an Econo column (Bio-Rad). The resin was washed with buffer C (20 mM Tris–HCl [pH 8.0], 0.3 M NaCl, 20 mM imidazole, and 3 mM β-mercaptoethanol), and the protein was eluted with buffer D (20 mM Tris–HCl [pH 8.0], 0.3 M NaCl, 300 mM imidazole, and 3 mM β-mercaptoethanol). The protein was then loaded onto a HiTrap SP HP column (Cytiva) equilibrated with buffer E (50 mM HEPES–KOH [pH 7.5], 0.3 M NaCl, and 0.5 mM TCEP). The protein was eluted using a linear gradient from 0.3 to 2.0 M NaCl over seven column volumes. It was further purified through size exclusion chromatography (Enrich SEC 650, Bio-Rad) with buffer F (50 mM HEPES–KOH [pH 7.5], 0.5 M NaCl, and 0.5 mM TCEP).
Chemically synthesized crRNAs targeting the N-gene of SARS-CoV-2 (GGAUUUAGAGUACCCCAAAAAUGAAGGGGACUAAAACAAGGUCUUCCUUGCCAUGUUGAGUGAGAGCGG) were purchased from GeneDesign or Hokkaido System Science. The FQ-reporter (FAM/rUrUrUrUrU/3lABkFQ) were purchased from IDT. The viral RNA fragment (N-gene, SARS-CoV-2) was transcribed in vitro with T7 RNA polymerase at 37 °C for 1 h, using a partially double-stranded DNA template. To remove the double-stranded RNA contaminations, the transcribed RNA was incubated with RNaseIII (New England Biolabs) at 37 °C for 30 min, and then purified by 8% native polyacrylamide gel electrophoresis. The RNA concentration was determined from the A260 value measured by the NanoDrop spectrophotometer.
The assay solution for SATORI (solution A) for a single assay was prepared as follows: To prepare Cas13a-crRNA complexes, a mixture of 0.7 μL of Cas13a (20 μM), 1.4 μL of crRNA, and 2.6 μL of buffer G (20 mM HEPES–KOH [pH 6.8], 60 mM NaCl, 6 mM MgCl2, and 50 μM Triton X-100) was incubated at 37 °C for 10 min. Next, 4.7 μL of Cas13a-crRNA solution was mixed with 18.7 μL of buffer H (20 mM HEPES–KOH [pH 7.5], 100 mM NaCl, 10 mM MgCl2, 50 μM Triton X-100, 15 μM FQ-reporter, and 15 μM Alexa 568) and stored at − 80 °C until use.
Before starting the SATORI assay, frozen solution A was thawed at 25 °C. Then 20 μL of solution A was mixed with 100 μL of target RNA solution. After 1 min of incubation, 105 μL of the mixture was dropped onto an femtoliter chamber array. Of the 105-μL solution on the array, 95 μL was removed, and 50 μL of Fomblin oil was added to seal the chamber. The excess solution A and Fomblin oil remaining on the array were removed. After 5 min of incubation, fluorescence tiling images were acquired using a confocal microscope (A1HD25, Nikon) with 25-stage scanning, acquired with 488 nm (green) and 561 nm lasers (red) with a 20 × objective lens (NA = 0.75).
The fluorescence images were analyzed using the ImageJ software as follows: the green images were processed using the ImageJ setThreshold command (parameters: 200–65,535), Analyze Particles command (parameters: size = 200–Infinity, circularity = 0.00–1.00), and roiManager (parameter: Fill) to remove large defective areas originating from the liquid sumps. The green images without defective areas were further processed using the setThreshold command (parameters: 1500–65,535) and Analyze Particles command (parameters: size = 15–Infinity, circularity = 0.40–1.00) to determine the positive chambers.
The analytical limit of detection (LoD) was defined as follows: the number of positive chambers obtained with different concentrations of the viral RNA fragment (vRNA) was fitted to a linear curve. The mean + 3 SD value for the number of positive chambers obtained without vRNA was determined, and the crossing point of the linear curve and the mean + 3 SD value were then determined. The concentration corresponding to the crossing point was defined as the LoD value.
HRP was purchased from Fujifilm Wako Chemicals (# 169-10791). HRP concentration was determined by BCA method using the molecular weight of HRP as 40.2 kDa. Amplex Red, a fluorogenic substrate for HRP, was purchased from Invitrogen (# A12222). β-Gal was purchased from MP Biomedicals (#104939). β-Gal concentration was determined by BCA method, using a molecular weight of tetrameric β-Gal as 540 kDa. Resorufin-β-D-galactopyranoside (RGP), a fluorogenic substrate for β-Gal, was purchased from sigma Aldrich (# R4883).
For digital HRP assay, 20 μL of solution B (600 µM Amplex Red, 30 µM Alexa 647, 6 mM H2O2, 20 mM HEPES–KOH [pH 7.5], 100 mM NaCl, 10 mM MgCl2, and 50 μM Triton X-100) was mixed with 100 μL of solution C (Arbitrary concentration of HRP, 20 mM HEPES–KOH [pH 7.5], 100 mM NaCl, 10 mM MgCl2, and 50 μM Triton X-100). Just after mixing these two solutions, 105 μL of the mixture was dropped onto an femtoliter chamber array. Of the 105-μL solution on the array, 95 μL was removed, and 50 μL of Fomblin oil was added to seal the chamber. The excess solution and Fomblin oil remaining on the array were removed. After 8 min of incubation, fluorescence tiling images were acquired using a confocal microscope (A1HD25, Nikon) with 25-stage scanning, acquired with 561 nm (green) and 640 nm lasers (red) with a 20 × objective lens (NA = 0.75).
For digital β-Gal assay, 20 μL of solution D (600 µM RGP, 30 µM Alexa 647, 20 mM HEPES–KOH [pH 7.5], 100 mM NaCl, 10 mM MgCl2, and 50 μM Triton X-100) was mixed with 100 μL of solution E (Arbitrary concentration of β-Gal, 20 mM HEPES–KOH [pH 7.5], 100 mM NaCl, 10 mM MgCl2, and 50 μM Triton X-100). Just after mixing these two solutions, 105 μL of the mixture was dropped onto an femtoliter chamber array. Of the 105-μL solution on the array, 95 μL was removed, and 50 μL of Fomblin oil was added to seal the chamber. The excess solution and Fomblin oil remaining on the array were removed. After 4 min of incubation, fluorescence tiling images were acquired using a confocal microscope (A1HD25, Nikon) with 25-stage scanning, acquired with 561 nm (green) and 640 nm lasers (red) with a 20 × objective lens (NA = 0.75).
The fluorescence images were analyzed using the ImageJ software as follows: the green images were processed using the ImageJ setThreshold command (parameters: 600–65535), Analyze Particles command (parameters: size = 200–Infinity, circularity = 0.00–1.00), and roiManager (parameter: Fill) to remove large defective areas originating from the liquid sumps. The green images without defective areas were further processed using the setThreshold command (parameters: 900–65535) and Analyze Particles command (parameters: size = 15–40, circularity = 0.50–1.00) to determine the positive chambers. The analytical limit of detection (LoD) was defined as follows: the number of positive chambers obtained with different concentrations of the target enzymes was fitted to a linear curve. The mean + 3 SD value for the number of positive chambers obtained without target enzymes was determined, and the crossing point of the linear curve and the mean + 3 SD value were then determined. The concentration corresponding to the crossing point was defined as the LoD value.
All data needed to evaluate the conclusions in the paper are provided in the paper and/or the Supplementary Materials.
Cohen, L. & Walt, D. R. Single-molecule arrays for protein and nucleic acid analysis. Annu. Rev. Anal. Chem. 10, 345–363 (2017).
Noji, H., Minagawa, Y. & Ueno, H. Enzyme-based digital bioassay technology—Key strategies and future perspectives. Lab Chip 22, 3092–3109 (2022).
Article CAS PubMed Google Scholar
Watanabe, R. et al. Arrayed lipid bilayer chambers allow single-molecule analysis of membrane transporter activity. Nat. Commun. 5, 4519 (2014).
Article ADS CAS PubMed Google Scholar
Watanabe , R. , Sakuragi , T. , Noji , H. & Nagata , S. Single-molecule analysis of phospholipid scrambling by TMEM16F. Proc. Natl. Acad. Sci. U.S.A. 115, 3066–3071 (2018).
Article ADS CAS PubMed PubMed Central Google Scholar
Sakamoto, S. et al. Multiplexed single-molecule enzyme activity analysis for counting disease-related proteins in biological samples. Sci. Adv. 6, eaay0888 (2020).
Article ADS CAS PubMed PubMed Central Google Scholar
Rissin, D. M. et al. Single-molecule enzyme-linked immunosorbent assay detects serum proteins at subfemtomolar concentrations. Nat. Biotechnol. 28, 595–599 (2010).
Article CAS PubMed PubMed Central Google Scholar
Huggett, J. F., Cowen, S. & Foy, C. A. Considerations for digital PCR as an accurate molecular diagnostic tool. Clin. Chem. 61, 79–88 (2015).
Article CAS PubMed Google Scholar
Wang, X., Ogata, A. F. & Walt, D. R. Ultrasensitive detection of enzymatic activity using single molecule arrays. J. Am. Chem. Soc. 142, 15098–15106 (2020).
Article CAS PubMed PubMed Central Google Scholar
Sakakihara , S. , Araki , S. , Iino , R. & Noji , H. A single-molecule enzymatic assay in a directly accessible femtoliter droplet array . Lab Chip 10, 3355–3362 (2010).
Article CAS PubMed Google Scholar
Wilson, D. H. et al. The Simoa HD-1 analyzer: A novel fully automated digital immunoassay analyzer with single-molecule sensitivity and multiplexing. J. Lab Autom. 21, 533–547 (2016).
Article CAS PubMed Google Scholar
Shinoda, H. et al. Automated amplification-free digital RNA detection platform for rapid and sensitive SARS-CoV-2 diagnosis. Commun. Biol. 5, 473 (2022).
Article CAS PubMed PubMed Central Google Scholar
Ueda, T. et al. Purification/amplification-free RNA detection platform for rapid and multiplex diagnosis of plant viral infections. Anal. Chem. 95, 9680–9686 (2023).
Article CAS PubMed Google Scholar
Kim, S. H. et al. Large-scale femtoliter droplet array for digital counting of single biomolecules. Lab Chip 12, 4986–4991 (2012).
Article CAS PubMed Google Scholar
Fenton, S. E. et al. Per‐ and polyfluoroalkyl substance toxicity and human health review: Current state of knowledge and strategies for informing future research. Environ. Toxicol. Chem. 40, 606–630 (2021).
Article CAS PubMed Google Scholar
Ando, J. & Watanabe, R. Toward versatile digital bioanalysis. Biomicrofluidics 17, 061303 (2023).
Article CAS PubMed PubMed Central Google Scholar
Sakamoto, S. et al. Identification of activity-based biomarkers for early-stage pancreatic tumors in blood using single-molecule enzyme activity screening. Cell Rep. Methods 4, 100688 (2024).
Article CAS PubMed PubMed Central Google Scholar
Nagano, N. et al. Development of fluorogenic substrates for colorectal tumor-related neuropeptidases for activity-based diagnosis. Chem. Sci. 14, 4495–4499 (2023).
Article CAS PubMed PubMed Central Google Scholar
Kaminski , MM , Abudayyeh , OO , Gootenberg , JS , Zhang , F & Collins , JJ CRISPR-based diagnostics . Nat. Biomed. Eng. 5, 643–656 (2021).
Article CAS PubMed Google Scholar
Avaro, A. S. & Santiago, J. G. A critical review of microfluidic systems for CRISPR assays. Lab Chip 23, 938–963 (2023).
Article CAS PubMed Google Scholar
Shinoda, H. et al. Amplification-free RNA detection with CRISPR–Cas13. Commun. Biol. 4, 476 (2021).
Article CAS PubMed PubMed Central Google Scholar
Park, J. S. et al. Digital CRISPR/Cas‐assisted assay for rapid and sensitive detection of SARS‐CoV‐2. Adv. Sci. 8, 2003564 (2021).
Iida, T. et al. Compact wide-field femtoliter-chamber imaging system for high-speed and accurate digital bioanalysis. Lab Chip 23, 684–691 (2023).
Article CAS PubMed Google Scholar
Iida, T., Shinoda, H. & Watanabe, R. SATORI: Amplification-free digital RNA detection method for the diagnosis of viral infections. Biophys. Physicobiol. 20, e200031 (2023).
Article CAS PubMed PubMed Central Google Scholar
We thank all members of the Watanabe laboratory and Mr. Honda from DAIKIN INDUSTRIES for their constructive discussions.
This work was supported by JST CREST (JPMJCR19H5), AMED (JP22he0422018, JP22fk0108542), and JSPS Grant-in-Aid for Transformative Research Areas A (20H05931) and Scientific Research A (21H04645) to R.W.; JSPS Grant-in-Aid for Scientific Research B (22H01996), Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering, and Konica Minolta Science and Technology Foundation to J.A.
Molecular Physiology Laboratory, Cluster for Pioneering Research, RIKEN, Saitama, Japan
Jun Ando, Kazue Murai, Makiko Mori, Tomoe Michiyuki, Tatsuya Iida, Asami Makino, Hajime Shinoda & Rikiya Watanabe
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
J.A. and R.W. designed the experiments; J.A., K.M., M.M., and T.M. fabricated femtoliter chamber arrays; T. I. and A.M. performed digital bioanalysis; H.S. explored experimental conditions; J.A. and R.W. wrote the manuscript.
Correspondence to Jun Ando or Rikiya Watanabe.
The authors declare no competing interests.
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Ando, J., Murai, K., Mori, M. et al. Exploring fluoropolymers for fabrication of femtoliter chamber arrays used in digital bioanalysis. Sci Rep 14, 11442 (2024). https://doi.org/10.1038/s41598-024-61726-8
DOI: https://doi.org/10.1038/s41598-024-61726-8
Anyone you share the following link with will be able to read this content:
Sorry, a shareable link is not currently available for this article.
Provided by the Springer Nature SharedIt content-sharing initiative
Scientific Reports (Sci Rep) ISSN 2045-2322 (online)
pvd coating process Sign up for the Nature Briefing: Translational Research newsletter — top stories in biotechnology, drug discovery and pharma.